Medical Journals

Comparison of the Use of New Handheld Tonometers and Established Applanation Tonometers in Dogs.

Authors:
  • Görig Christiane
  • Coenen Roel T I
  • Stades Frans C
  • Djajadiningrat-Laanen Sylvia C
  • Boevé Michael H

From: Department of Clinical Sciences of Companion Animals, Faculty of Veterinary Medicine, University of Utrecht, Yalelaan 8, 3508 TD Utrecht, The Netherlands.

American journal of veterinary research

  • Publish Date: Jan 2006
  • ISSN: 0002-9645
  • Volume: 67
  • Issue: 1
  • Pages: 134-44
  • Medium: Print
  • Language: English
  • Citation (JAMA): Görig Christiane, Coenen Roel T I, Stades Frans C, et al. Comparison of the Use of New Handheld Tonometers and Established Applanation Tonometers in Dogs.. Am. J. Vet. Res. Jan 2006;67:134-44

Abstract

OBJECTIVE: To examine the practical aspects, accuracy, and reproducibility of 2 new automatic handheld tonometers in dogs and compare them with results for 2 established applanation tonometers. ANIMALS: 15 freshly enucleated canine eyes for manometric evaluation and 20 conscious research dogs, 20 client-owned dogs, and 12 dogs with acute glaucoma for clinical tonometry. PROCEDURE: Calibration curves were determined for all 4 tonometers on 15 enucleated canine eyes. Intraocular pressure (IOP) was measured with each tonometer consecutively in conscious dogs, with the MacKay-Marg applanation tonometer as the reference device. Measurements were repeated in 20 sedated dogs. An induction-impact tonometer was evaluated clinically on dogs with acute glaucoma. Additionally, measurements obtained by an experienced and an inexperienced examiner and with or without use of topical anesthesia were compared. RESULTS: The portable pneumatonometer was cumbersome and time-consuming. Compared with results for the reference applanation tonometer, and confirmed by manometry, the portable pneumatonometer increasingly underestimated actual IOP values with increasing IOP. The induction-impact tonometer provided accurate and reproducible measurement values. There was a significant strong correlation between the IOP values obtained by the 2 examiners (r2, 0.82) and also with or without topical anesthesia (r2, 0.86). In dogs with glaucoma, the fitted line comparing values for the reference applanation tonometer and induction-impact tonometer closely resembled an ideal 1:1 relationship. CONCLUSIONS AND CLINICAL RELEVANCE: Use of the portable pneumatonometer in dogs appears to have disadvantages. The induction-impact tonometer appears to provide a promising alternative to the use of applanation tonometers in dogs.

Mesh Headings (Keywords): Animals, Dog Diseases, Dogs, Evaluation Studies as Topic, Glaucoma, Intraocular Pressure, Tonometry, Ocular


Check for Full Text / PubMed Unique Identifier (PMID): 16426223


This abstract is part of PubMed, a service of the U.S. National Library of Medicine. PubMed includes more than 17 million citations from MEDLINE and other life science journals for biomedical articles. See Copyright and Disclaimers.

Linked medical terms appearing on this page are added by Healia to help readers find more information and are not part of the original PubMed document.

The data herein was last updated on July 8th, 2008 and may not reflect the most current and accurate data available from NLM.


Advertisements

About | Privacy Policy | Business Solutions | Advertise | Contact | Add Healia to your site

©2012. Healia / Meredith Corporation  

Use of this site constitutes acceptance of our Terms of Service and Privacy Policy. All content on this Web site, including medical opinion and any other health-related information, is for informational purposes only and should not be used for a specific diagnosis or individual treatment plan for any situation. Use of this site and the information contained herein does not create a doctor-patient relationship. Always seek the direct advice of your doctor in connection with any questions or issues you may have regarding your own health or the health of others.