Medical Journals

Effect of Compliant Flooring on Impact Force During Falls on the Hip.

Authors:
  • Laing Andrew C
  • Tootoonchi Iman
  • Hulme Paul A
  • Robinovitch Stephen N

From: Injury Prevention and Mobility Laboratory, School of Kinesiology, Faculty of Applied Sciences, Simon Fraser University, 8888 University Drive, Burnaby, British Columbia, Canada V5A 1S6.

Journal of orthopaedic research : official publication of the Orthopaedic Research Society

  • Publish Date: Jul 2006
  • ISSN: 0736-0266
  • Volume: 24
  • Issue: 7
  • Pages: 1405-11
  • Medium: Print
  • Language: English
  • Citation (JAMA): Laing Andrew C, Tootoonchi Iman, Hulme Paul A, et al. Effect of Compliant Flooring on Impact Force During Falls on the Hip.. J. Orthop. Res. Jul 2006;24:1405-11

Abstract

Compliant flooring represents a promising but understudied strategy for reducing impact force and hip fracture risk due to falls in high-risk environments such as nursing homes, hospitals, gymnasiums, and senior centers. We conducted “pelvis release experiments” with young women (n=15) to determine whether floor stiffness influences peak hip impact force during safe, low-height falls. During the trials, we used a pelvic sling and electromagnet to lift and instantly release the participant from a height of 5 cm above a force plate, which measured the force applied to the hip region during impact. Trials were conducted for rigid floor conditions and with layers of ethylene vinyl acetate foam rubber overlying the floor that we regarded as firm (1.5-cm thick; stiffness=263 kN/m), semifirm (4.5-cm thick; stiffness=95 kN/m), semisoft (7.5-cm thick; stiffness=67 kN/m), and soft (10.5-cm thick; stiffness=59 kN/m). When compared to the rigid condition, peak hip impact force averaged 8% lower in the firm condition and 15% lower in the semifirm condition. Peak forces were not significantly different between the semifirm, semisoft, and soft floor conditions, indicating that a 4.5 cm-thick foam mat provides nearly the same force attenuation as a 10.5 cm-thick mat. These results support the need for laboratory experiments to measure the effect of floor stiffness on postural stability and for clinical trials to determine the effect of compliant flooring on hip fracture incidence in high-risk environments.

Mesh Headings (Keywords): Accidental Falls, Adult, Biomechanics, Compliance, Female, Floors and Floorcoverings, Hip, Humans


Check for Full Text / PubMed Unique Identifier (PMID): 16705716


This abstract is part of PubMed, a service of the U.S. National Library of Medicine. PubMed includes more than 17 million citations from MEDLINE and other life science journals for biomedical articles. See Copyright and Disclaimers.

Linked medical terms appearing on this page are added by Healia to help readers find more information and are not part of the original PubMed document.

The data herein was last updated on July 8th, 2008 and may not reflect the most current and accurate data available from NLM.


Advertisements

About | Privacy Policy | Business Solutions | Advertise | Contact | Add Healia to your site

©2012. Healia / Meredith Corporation  

Use of this site constitutes acceptance of our Terms of Service and Privacy Policy. All content on this Web site, including medical opinion and any other health-related information, is for informational purposes only and should not be used for a specific diagnosis or individual treatment plan for any situation. Use of this site and the information contained herein does not create a doctor-patient relationship. Always seek the direct advice of your doctor in connection with any questions or issues you may have regarding your own health or the health of others.