Fasting Blood Glucose Levels Are Related to Exercise Capacity in Patients with Coronary Artery Disease.
From: Department of Cardiovascular Diseases, Ghent University, Ghent, Belgium. nico.vandeveire@ugent.be
American heart journal
- Publish Date: Sep 2006
- ISSN: 1097-6744
- Volume: 152
- Issue: 3
- Pages: 486-92
- Medium: Internet
- Language: English
- Citation (JAMA): Van de Veire Nico R, De Winter Olivier, Gir Mimi, et al. Fasting Blood Glucose Levels Are Related to Exercise Capacity in Patients with Coronary Artery Disease.. Am. Heart J. Sep 2006;152:486-92
Abstract
BACKGROUND AND AIM: Previous studies have demonstrated reduced exercise capacity in patients with diabetes mellitus. This study evaluated the relationship between fasting blood glucose (FBG) levels and exercise capacity in patients with coronary artery disease (CAD). METHODS: We evaluated 986 consecutive patients with CAD referred for bicycle spiroergometry combined with gated myocardial perfusion imaging. Maximum oxygen consumption (VO2max) and maximal watts were measured. Patients were divided into 4 FBG categories: < 100 mg/dL (n = 611), 100 to 109 mg/dL (n = 144), 110 to 125 mg/dL (n = 102), and > or = 126 mg/dL (n = 129). Differences in clinical characteristics, exercise hemodynamics, perfusion imaging, and univariate as well as multivariate predictors of exercise capacity were determined. RESULTS: Maximal watts and VO2max were significantly lower (P < .0001) in patients with higher FBG levels and were related to FBG values in univariate and multivariate analyses. Left ventricular volumes and ejection fractions did not differ between the FBG categories. Myocardial perfusion imaging showed a comparable degree of ischemia in the 4 FBG groups. However, patients with higher FBG levels had higher heart rate and blood pressure values at rest resulting in a higher rate-pressure product (values in the 4 FBG groups 8299 +/- 2051, 8733 +/- 2008, 9558 +/- 2583, and 9588 +/- 2468 beat/min x mm Hg, P < .0001), suggesting increased myocardial oxygen consumption per unit time at rest. CONCLUSION: Exercise capacity in patients with CAD is related to FBG levels. Patients with impaired fasting glucose or an FBG level > or = 126 mg/dL reached lower peak watts and lower VO2max values. This could be attributed to a higher myocardial oxygen consumption per unit time at rest and the inability to adapt their coronary flow adequately to higher metabolic demands during maximal exercise.
Mesh Headings (Keywords): Aged, Blood Glucose, Coronary Artery Disease, Databases, Factual, Exercise Test, Exercise Tolerance, Fasting, Female, Humans, Male, Middle Aged, Multivariate Analysis, Oxygen Consumption
Check for Full Text / PubMed Unique Identifier (PMID): 16923418
This abstract is part of PubMed, a service of the U.S. National Library of Medicine. PubMed includes more than 17 million citations from MEDLINE and other life science journals for biomedical articles. See Copyright and Disclaimers.
Linked medical terms appearing on this page are added by Healia to help readers find more information and are not part of the original PubMed document.
The data herein was last updated on July 8th, 2008 and may not reflect the most current and accurate data available from NLM.
