Medical Journals

A Biomechanical Analysis of Sublaminar and Subtransverse Process Fixation Using Metal Wires and Polyethylene Cables.

Authors:
  • Fujita Masaru
  • Diab Mohammad
  • Xu Zheng
  • Puttlitz Christian M

From: Department of Orthopaedic Surgery, University of California at San Francisco, USA.

Spine

  • Publish Date: Sep 2006
  • ISSN: 1528-1159
  • Volume: 31
  • Issue: 19
  • Pages: 2202-8
  • Medium: Internet
  • Language: English
  • Citation (JAMA): Fujita Masaru, Diab Mohammad, Xu Zheng, et al. A Biomechanical Analysis of Sublaminar and Subtransverse Process Fixation Using Metal Wires and Polyethylene Cables.. Spine Sep 2006;31:2202-8

Abstract

STUDY DESIGN: An in vitro biomechanical calf thoracic spine study. OBJECTIVE: To evaluate the biomechanical stability of sublaminar and subtransverse process fixation using stainless steel wires and ultra-high molecular weight polyethylene (UHMWPE) cables. SUMMARY OF BACKGROUND DATA: It is commonly held that transverse process fixation provides less stability than sublaminar fixation. To our knowledge, this is the first biomechanical study to compare the stability afforded by sublaminar fixation and subtransverse process fixation using metal wire and UHMWPE cable before and after cyclic loading. METHODS: There were 6 fresh-frozen calf thoracic spines (T4-T9) used to determine the sublaminar fixation stiffness and subtransverse process fixation stiffness in each group. Double strands of 18-gauge stainless steel wire, 3 and 5 mm-width UHMWPE cable (Nesplon; Alfresa, Inc., Osaka, Japan) were applied to each spine. Cyclic pure flexion-extension moment loading (2 Nm, 0.5 Hz, 5000 cycles) was applied after the initial stability was analyzed by measuring the range of motion. Statistical analyses were used to delineate differences between the various experimental groups. RESULTS: Subtransverse process wiring was more stable than sublaminar wiring after cyclic loading in flexion-extension (P < 0.05). There were no significant differences between each group in lateral bending and axial rotation after cyclic loading. Sublaminar stainless steel wiring was more stable than sublaminar 3 and 5-mm cable before and after cyclic loading in axial rotation (P < 0.01). Acute subtransverse process fixation using 3-mm cable was less stable after cyclic loading in axial rotation (P < 0.05). All other groups did not produce statistically significant differences. CONCLUSIONS: Subtransverse process fixation provides at least as much stability as sublaminar fixation. A 5-mm UHMWPE cable and stainless steel wire result in equivalent sublaminar and subtransverse process stability.

Mesh Headings (Keywords): Animals, Biocompatible Materials, Biomechanics, Bone Wires, Cattle, Internal Fixators, Joint Instability, Polyethylene, Spinal Fusion, Stainless Steel, Thoracic Vertebrae


Check for Full Text / PubMed Unique Identifier (PMID): 16946654


This abstract is part of PubMed, a service of the U.S. National Library of Medicine. PubMed includes more than 17 million citations from MEDLINE and other life science journals for biomedical articles. See Copyright and Disclaimers.

Linked medical terms appearing on this page are added by Healia to help readers find more information and are not part of the original PubMed document.

The data herein was last updated on July 8th, 2008 and may not reflect the most current and accurate data available from NLM.


Advertisements

About | Privacy Policy | Business Solutions | Advertise | Contact | Add Healia to your site

©2012. Healia / Meredith Corporation  

Use of this site constitutes acceptance of our Terms of Service and Privacy Policy. All content on this Web site, including medical opinion and any other health-related information, is for informational purposes only and should not be used for a specific diagnosis or individual treatment plan for any situation. Use of this site and the information contained herein does not create a doctor-patient relationship. Always seek the direct advice of your doctor in connection with any questions or issues you may have regarding your own health or the health of others.