Medical Journals

The Effect of Plate Rotation on the Stiffness of Femoral Liss: a Mechanical Study.

Authors:
  • Khalafi Afshin
  • Curtiss Shane
  • Hazelwood Scott
  • Wolinsky Philip

From: Department of Orthopaedic Surgery, University of California, Davis, Sacramento, CA 95817, USA. afshin.khalafi@ucdmc.ucdavis.edu

Journal of orthopaedic trauma

  • Publish Date: Sep 2006
  • ISSN: 0890-5339
  • Volume: 20
  • Issue: 8
  • Pages: 542-6
  • Medium: Print
  • Language: English
  • Citation (JAMA): Khalafi Afshin, Curtiss Shane, Hazelwood Scott, et al. The Effect of Plate Rotation on the Stiffness of Femoral Liss: a Mechanical Study.. Sep 2006;20:542-6

Abstract

OBJECTIVE: Malposition of the femoral Less Invasive Stabilization System (LISS) plate may alter its biomechanical behavior. This study compares the mechanical stability of “correctly” affixed LISS plates matching the slope of the lateral femoral condyle to “incorrectly” placed LISS plates fixed in external rotation relative to the distal femur. METHODS: A fracture gap model was created to simulate a comminuted supracondylar femur fracture (AO/OTA33-A3). Fixation was achieved using two different plate positions: the LISS plate was either placed “correctly” by internally rotating the plate to match the slope of the lateral femoral condyle, or “incorrectly” by externally rotating the plate relative to the distal femur. Following fixation, the constructs were loaded in axial, torsional, and cyclical axial modes in a material testing machine. MAIN OUTCOME MEASUREMENT: Stiffness in axial and torsional loading; total deformation and irreversible (plastic) deformation in cyclical axial loading. RESULTS: The mean axial stiffness for the correctly placed LISS constructs was 21.5% greater than the externally rotated LISS constructs (62.7 N/mm vs. 49.3 N/mm; P = 0.0007). No significant difference was found in torsional stiffness between the two groups. Cyclical axial loading caused significantly less (P < 0.0001) plastic deformation in the correct group (0.6 mm) compared with externally rotated group (1.3 mm). All the constructs in the incorrect group failed, where failure was defined as a complete closure of the medial fracture gap, prior to completion of the test cycles. CONCLUSION: Correct positioning of the LISS plate for fixation of distal femur fractures results in improved mechanical stability as reflected by an increased stiffness in axial loading and decreased plastic deformation at the bone-screw interface.

Mesh Headings (Keywords): Biomechanics, Bone Plates, Equipment Design, Femoral Fractures, Fracture Fixation, Humans


Check for Full Text / PubMed Unique Identifier (PMID): 16990725


This abstract is part of PubMed, a service of the U.S. National Library of Medicine. PubMed includes more than 17 million citations from MEDLINE and other life science journals for biomedical articles. See Copyright and Disclaimers.

Linked medical terms appearing on this page are added by Healia to help readers find more information and are not part of the original PubMed document.

The data herein was last updated on July 8th, 2008 and may not reflect the most current and accurate data available from NLM.


Advertisements

About | Privacy Policy | Business Solutions | Advertise | Contact | Add Healia to your site

©2012. Healia / Meredith Corporation  

Use of this site constitutes acceptance of our Terms of Service and Privacy Policy. All content on this Web site, including medical opinion and any other health-related information, is for informational purposes only and should not be used for a specific diagnosis or individual treatment plan for any situation. Use of this site and the information contained herein does not create a doctor-patient relationship. Always seek the direct advice of your doctor in connection with any questions or issues you may have regarding your own health or the health of others.