Medical Journals

Borate Protection of Softwood from Coptotermes Acinaciformis (Isoptera: Rhinotermitidae) Damage: Variation in Protection Thresholds Explained.

Authors:
  • Peters Brenton C
  • Fitzgerald Christopher J

From: Department of Primary Industries and Fisheries, Forestry Building, Gate 3, 80 Meiers Road, Indooroopilly, Queensland 4068, Australia. brenton.peters@dpi.qld.gov.au

Journal of economic entomology

  • Publish Date: Oct 2006
  • ISSN: 0022-0493
  • Volume: 99
  • Issue: 5
  • Pages: 1749-56
  • Medium: Print
  • Language: English
  • Citation (JAMA): Peters Brenton C, Fitzgerald Christopher J, et al. Borate Protection of Softwood from Coptotermes Acinaciformis (Isoptera: Rhinotermitidae) Damage: Variation in Protection Thresholds Explained.. J. Econ. Entomol. Oct 2006;99:1749-56

Abstract

Laboratory and field data reported in the literature are confusing with regard to “adequate” protection thresholds for borate timber preservatives. The confusion is compounded by differences in termite species, timber species and test methodology. Laboratory data indicate a borate retention of 0.5% mass/mass (m/m) boric acid equivalent (BAE) would cause > 90% termite mortality and restrict mass loss in test specimens to < or = 5%. Field data generally suggest that borate retentions appreciably > 0.5% m/m BAE are required. We report two field experiments with varying amounts of untreated feeder material in which Coptotermes acinaciformis (Froggatt) (Isoptera: Rhinotermitidae) responses to borate-treated radiata (Monterey) pine, Pinus radiata D. Don, were measured. The apparently conflicting results between laboratory and field data are explained by the presence or absence of untreated feeder material in the test environment. In the absence of untreated feeder material, wood containing 0.5% BAE provided adequate protection from Coptotermes sp., whereas in the presence of untreated feeder material, increased retentions were required. Furthermore, the retentions required increased with increased amounts of susceptible material present. Some termites, Nasutitermes sp. and Mastotermes darwiniensis Froggatt, for example, are borate-tolerant and borate timber preservatives are not a viable management option with these species. The lack of uniform standards for termite test methodology and assessment criteria for efficacy across the world is recognized as a difficulty with research into the performance of timber preservatives with termites. The many variables in laboratory and field assays make “prescriptive” standards difficult to recommend. The use of “performance” standards to define efficacy criteria (“adequate” protection) is discussed.

Mesh Headings (Keywords): Animals, Australia, Borates, Isoptera, Pinus


Check for Full Text / PubMed Unique Identifier (PMID): 17066808


This abstract is part of PubMed, a service of the U.S. National Library of Medicine. PubMed includes more than 17 million citations from MEDLINE and other life science journals for biomedical articles. See Copyright and Disclaimers.

Linked medical terms appearing on this page are added by Healia to help readers find more information and are not part of the original PubMed document.

The data herein was last updated on July 8th, 2008 and may not reflect the most current and accurate data available from NLM.


Advertisements

About | Privacy Policy | Business Solutions | Advertise | Contact | Add Healia to your site

©2012. Healia / Meredith Corporation  

Use of this site constitutes acceptance of our Terms of Service and Privacy Policy. All content on this Web site, including medical opinion and any other health-related information, is for informational purposes only and should not be used for a specific diagnosis or individual treatment plan for any situation. Use of this site and the information contained herein does not create a doctor-patient relationship. Always seek the direct advice of your doctor in connection with any questions or issues you may have regarding your own health or the health of others.