Medical Journals

Biomechanics of Two-level Charité Artificial Disc Placement in Comparison to Fusion Plus Single-level Disc Placement Combination.

Authors:
  • Grauer Jonathan N
  • Biyani Ashok
  • Faizan Ahmad
  • Kiapour Ali
  • Sairyo Koichi
  • Ivanov Alex
  • Ebraheim Nabil A
  • Patel Tushar Ch
  • Goel Vijay K

From: Department of Orthopedics and Rehabilitation, Yale University School of Medicine, New Haven, CTUSA.

The spine journal : official journal of the North American Spine Society

  • Publish Date:
  • ISSN: 1529-9430
  • Volume: 6
  • Issue: 6
  • Pages: 659-66
  • Medium: Print
  • Language: English
  • Citation (JAMA): Grauer Jonathan N, Biyani Ashok, Faizan Ahmad, et al. Biomechanics of Two-level Charité Artificial Disc Placement in Comparison to Fusion Plus Single-level Disc Placement Combination.. ;6:659-66

Abstract

BACKGROUND CONTEXT: Biomechanical studies of artificial discs that quantify parameters such as load sharing and stresses have been reported in literature for single-level disc placements. However, literature on the effects of using the Charité artificial disc (ChD) at two levels (2LChD) as compared with one-level fusion (using a cage [CG] and a pedicle screw system) plus one-level artificial disc combination (CGChD) is sparse. PURPOSE: To determine the effects of the 2LChD and CGChD across the implanted and adjacent segments. STUDY DESIGN: A finite element model of a L3-S1 segment was used to compare the biomechanical effects of the ChD placed at two lower levels (2LChD model) with L5-S1 fusion (using a CG and a pedicle screw system) plus L4-L5 level ChD placement combination (CGChD model). METHODS: We used our recently published and experimentally validated L3-S1 finite element model for the present study. The intact model was subjected to 400 N axial compression and 10.6 Nm of flexion/extension moments. The experimental constructs described above were then subjected to 400 N axial compression and a moment that produced overall motion equal to the intact model predictions (hybrid testing protocol). Resultant motion, loads across facets, and other parameters were analyzed at the experimental and adjacent levels. RESULTS: In flexion, the bending moments for the CGChD and 2LChD models were 15.4 Nm (fusion effect) and 7.3 Nm (increase in flexibility effect), respectively in comparison to 10.6 Nm for the intact model. The corresponding values in the extension mode were 11.2 Nm and 7.2 Nm. The predicted flexion rotations across the L5-S1 segment for the CGChD decreased by 76% (fusion effect), and increased at the L4-L5 and the L3-L4 levels by 68.5% and 28%, respectively. In the extension mode, motion across the L5-S1 segment decreased by 96.4% whereas it increased 74.6% and 18.2% across the L4-L5 and L3-L4 levels, respectively. For the 2LChD model, the flexion rotation across the L5-S1 segment increased by 28.2%. The motions across the L4-L5 and L3-L4 segments decreased by 12% and 24%, respectively. In extension, the corresponding changes were 10% increase, 10% increase, and 21% decrease at the L5-S1, L4-L5, and L3-L4 levels, respectively. The facet loads were in line with the changes in motion, except for the 2LChD case. CONCLUSIONS: The changes at L3-L4 level for both of the cases were of similar magnitude (approximately 25%), although in the CGChD model it increased and in the 2LChD model it decreased. The changes in motion at the L4-L5 level were large for the CGChD model as compared with the 2LChD model predictions (approximately 70% increase vs. 10% increase). It is difficult to speculate if an increase in motion across a segment, as compared with the intact case, is more harmful than a decrease in motion.

Mesh Headings (Keywords): Biomechanics, Finite Element Analysis, Humans, Intervertebral Disk, Lumbar Vertebrae, Models, Neurological, Range of Motion, Articular, Spinal Fusion


Check for Full Text / PubMed Unique Identifier (PMID): 17088196


This abstract is part of PubMed, a service of the U.S. National Library of Medicine. PubMed includes more than 17 million citations from MEDLINE and other life science journals for biomedical articles. See Copyright and Disclaimers.

Linked medical terms appearing on this page are added by Healia to help readers find more information and are not part of the original PubMed document.

The data herein was last updated on July 8th, 2008 and may not reflect the most current and accurate data available from NLM.


Advertisements

About | Privacy Policy | Business Solutions | Advertise | Contact | Add Healia to your site

©2012. Healia / Meredith Corporation  

Use of this site constitutes acceptance of our Terms of Service and Privacy Policy. All content on this Web site, including medical opinion and any other health-related information, is for informational purposes only and should not be used for a specific diagnosis or individual treatment plan for any situation. Use of this site and the information contained herein does not create a doctor-patient relationship. Always seek the direct advice of your doctor in connection with any questions or issues you may have regarding your own health or the health of others.