The Mechanism of Extracellular Stimulation of Nerve Cells on an Electrolyte-oxide-semiconductor Capacitor.
From: Department of Membrane and Neurophysics, Max Planck Institute for Biochemistry, Martinsried/Munich, Germany.
Biophysical journal
- Publish Date: Feb 2007
- ISSN: 0006-3495
- Volume: 92
- Issue: 3
- Pages: 1096-111
- Medium: Print
- Language: English
- Citation (JAMA): Schoen Ingmar, Fromherz Peter, et al. The Mechanism of Extracellular Stimulation of Nerve Cells on an Electrolyte-oxide-semiconductor Capacitor.. Biophys. J. Feb 2007;92:1096-111
Abstract
Extracellular excitation of neurons is applied in studies of cultured networks and brain tissue, as well as in neuroprosthetics. We elucidate its mechanism in an electrophysiological approach by comparing voltage-clamp and current-clamp recordings of individual neurons on an insulated planar electrode. Noninvasive stimulation of neurons from pedal ganglia of Lymnaea stagnalis is achieved by defined voltage ramps applied to an electrolyte/HfO2/silicon capacitor. Effects on the smaller attached cell membrane and the larger free membrane are distinguished in a two-domain-stimulation model. Under current-clamp, we study the polarization that is induced for closed ion channels. Under voltage-clamp, we determine the capacitive gating of ion channels in the attached membrane by falling voltage ramps and for comparison also the gating of all channels by conventional variation of the intracellular voltage. Neuronal excitation is elicited under current-clamp by two mechanisms: Rising voltage ramps depolarize the free membrane such that an action potential is triggered. Falling voltage ramps depolarize the attached membrane such that local ion currents are activated that depolarize the free membrane and trigger an action potential. The electrophysiological analysis of extracellular stimulation in the simple model system is a basis for its systematic optimization in neuronal networks and brain tissue.
Mesh Headings (Keywords): Action Potentials, Animals, Cells, Cultured, Electric Capacitance, Electric Stimulation, Equipment Design, Equipment Failure Analysis, Extracellular Fluid, Lymnaea, Microelectrodes, Models, Neurological, Neurons, Semiconductors
Check for Full Text / PubMed Unique Identifier (PMID): 17098803
This abstract is part of PubMed, a service of the U.S. National Library of Medicine. PubMed includes more than 17 million citations from MEDLINE and other life science journals for biomedical articles. See Copyright and Disclaimers.
Linked medical terms appearing on this page are added by Healia to help readers find more information and are not part of the original PubMed document.
The data herein was last updated on January 1st, 1970 and may not reflect the most current and accurate data available from NLM.